• Skip to primary navigation
  • Skip to main content
  • Skip to footer
Prior Scientific

Prior Scientific

Experts in Precision Positioning and Microscope Automation

  • Products
    • Automated Imaging Systems
      • OpenStand-U
      • OpenStand-M
      • OpenStand-L
      • OpenStand-V
    • Imaging Components
      • Motorized Stages
      • Focus Mechanisms
      • Laser Autofocus
      • Filter Wheels, Turrets & Shutters
      • Controllers & Joysticks
      • Robotic Sample Loaders
      • Physiology Platforms
      • Motorized Vertical Stages
    • Microscope Automation
      • Evident Olympus Microscope Automation
      • Nikon Microscope Automation
      • Leica Microscope Automation
      • Zeiss Microscope Automation
      • Automated Custom Imaging Systems
      • Other Microscope Brands
    • Nanopositioning Devices
    • Vibration Control
    • Custom Solutions & Contract Manufacturing
  • About
  • Applications
  • Blog
  • Contact Us
  • News
  • Technical Support
  • US Shop
  • United States
    • English
    • Deutsch
    • 日本語
    • 简体中文
  • Automated Imaging Systems
    • OpenStand-L
    • OpenStand-M
    • OpenStand-U
    • OpenStand-V
  • Imaging Components
    • Motorized Stages
    • Focus Mechanisms
    • Laser Autofocus
    • Filter Wheels, Turrets & Shutters
    • Controllers & Joysticks
    • Robotic Sample Loaders
    • Physiology Platforms
    • Motorized Vertical Stages
  • Microscope Automation
    • Evident Olympus Microscope Automation
    • Nikon Microscope Automation
    • Leica Microscope Automation
    • Zeiss Microscope Automation
    • Automated Custom Imaging Systems
    • Other Microscope Brands
  • Nanopositioning Devices
  • Vibration Control
  • Custom Solutions & Contract Manufacturing
Home » Imaging Components » Motorized Stages » ProScan H105N2F Motorized XY Stage
H105 motorized XY flat-top stage designed for upright industrial microscopes with OEM and batch order flash.

ProScan H105N2F Motorized XY Stage


Flat Top 6-inch Semiconductor Scanning For Upright Microscopes (154 mm x 154 mm travel)

Flat Top 6-inch Semiconductor Scanning For Upright Microscopes (154 mm x 154 mm travel)

The ProScan H105N2F is a motorized XY flat-top stage designed for upright industrial microscopes. 

It is fully customizable for integration into OEM devices but also mounts directly onto Nikon industrial microscopes and the Prior OpenStand-L platform. See the product compatibility tab for details.

With 154 x 154 mm XY travel, it is optimized for scanning 6-inch semiconductor wafers and other industrial samples.

The H105N2F scans industrial samples reliably and efficiently. It features Prior’s patented Intelligent Scanning Technology (IST) to enhance accuracy and linearity, together with a 2 mm ballscrew for speed. 

The H105E2F encoded version is also available with 0.1 μm linear encoders to enhance long-range repeatability, accuracy, and linearity and reliably locates specific regions.

The flat top plate allows easy access to the sample for loading and ensures compatibility with a wide range of optics. 

It is compatible with Nikon NIS Elements software (appropriate package required).

This is an ‘OEM & Batch Order’ product. For more information visit our FAQs section.

Enquire
Data sheet
  • Easy to integrate into customized imaging solutions
  • Directly compatible with Nikon industrial microscopes and software
  • Aesthetic and user friendly flat top design
  • Travel range supports 6-inch wafers
  • Intelligent Scanning Technology™ (US Patent 7,330,307)
Travel range 154 mm x 154 mm
Bidirectional repeatability < 3.6 μm
Metric accuracy < 0.21 μm/mm
Full travel metric accuracy < 21.8 μm
Resolution 0.04 μm
Squareness 40 arcsec
Maximum velocity 40 mm/s
Maximum load 10 kg
Encoders No
Motor type 200 step
Screw pitch 2 mm
Weight 4.8 kg
  • H227 Glass plate (not suitable for transmitted light microscopy)
  • H231 Aluminium plate (H105)
  • H231B Aluminium plate (H105) with M4 and M6 tapped holes
  • HWC15S Wafer chuck, rotatable with steps for 100 mm and 150 mm wafers
  • HWC15V Wafer chuck, rotatable for vacuum for 150 mm wafers

H105N2F-EN-Datasheet.pdf

Download

Nikon-EN-US-Sales-Guide.pdf

Download

H105F-REFERENCE-PART-NONAMES.zip

Download
OptionManufacturerCompatibilityNotes
H105N2FPriorOpenStand-L
H105E2FPriorOpenStand-L
H105N2FNikonL200N, L200ND, L300N, L300ND
H105E2FNikonL200N, L200ND, L300N, L300ND

Related Products

ProScan III Multi-Axis Controller

ProScan III Multi-Axis Controller

View Product

PS3H122R (Nikon) Motorized Focus Drive

PS3H122R (Nikon) Motorized Focus Drive

View Product

PureFocus™850 Laser Autofocus System

PureFocus™850 Laser Autofocus System

View Product

Would you like to know more about our systems and components?

    +44 (0)1223 881711

    inquiries@prior.com

    Find your local office

    Footer

    Products

    • Automated Imaging Systems
    • Imaging Components
    • Microscope Automation
    • Nanopositioning Devices

    Company

    • Custom Solutions & Contract Manufacturing
    • Applications
    • Technical Support
    • Careers

    Resources

    • About
    • Blog
    • News
    • Contact Us

      Sign up to stay in the know...

      ✉

      Connect with us

      Prior Scientific Instruments Ltd.
      Units 3-4 Fielding Industrial Estate
      Wilbraham Road, Fulbourn
      Cambridge, CB21 5ET, UK

      inquiries@prior.com
      +44 (0)1223 881711

      Prior Scientific Inc.
      80 Reservoir Park Drive
      Rockland, MA. 02370
      U.S.A.

      info@prior.com
      +1 781 878 8442

      Prior Scientific Instruments GmbH
      Maria-Pawlowna-Str. 4
      07743 Jena
      Germany

      jena@prior.com
      +49 (0)3641 242 010

      Prior Scientific KK
      Kayabacho 3rd Nagaoka Bldg 10F,
      2-7-10, Nihonbashi Kayabacho
      Chuo-Ku, Tokyo 103-0025, Japan

      info-japan@prior.com
      +81 (0)3 5652 8831

      Prior Scientific Instruments (Suzhou) Ltd.
      Room 118, Meilihua Hemu Park,
      No. 393 Suhong Middle Road,
      Suzhou Industrial Park,
      Suzhou, 215000, China

      info-china@prior.com
      +86 (0)512 6617 5866

      Copyright © 2026 · Prior Scientific. Terms & Conditions | Privacy Policy | Impressum

      Manage Consent
      To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
      Functional Always active
      The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
      Preferences
      The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
      Statistics
      The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
      Marketing
      The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
      • Manage options
      • Manage services
      • Manage {vendor_count} vendors
      • Read more about these purposes
      View preferences
      • {title}
      • {title}
      • {title}