• Skip to primary navigation
  • Skip to main content
  • Skip to footer
Prior Scientific

Prior Scientific

Experts in Precision Positioning and Microscope Automation

  • Products
    • Automated Imaging Systems
      • OpenStand-U
      • OpenStand-M
      • OpenStand-L
      • OpenStand-V
    • Imaging Components
      • Motorized Stages
      • Focus Mechanisms
      • Laser Autofocus
      • Filter Wheels, Turrets & Shutters
      • Controllers & Joysticks
      • Robotic Sample Loaders
      • Physiology Platforms
      • Motorized Vertical Stages
    • Microscope Automation
      • Evident Olympus Microscope Automation
      • Nikon Microscope Automation
      • Leica Microscope Automation
      • Zeiss Microscope Automation
      • Automated Custom Imaging Systems
      • Other Microscope Brands
    • Nanopositioning Devices
    • Vibration Control
    • Custom Solutions & Contract Manufacturing
  • About
  • Applications
  • Blog
  • Contact Us
  • News
  • Technical Support
  • US Shop
  • United States
    • English
    • Deutsch
    • 日本語
    • 简体中文
  • Automated Imaging Systems
    • OpenStand-L
    • OpenStand-M
    • OpenStand-U
    • OpenStand-V
  • Imaging Components
    • Motorized Stages
    • Focus Mechanisms
    • Laser Autofocus
    • Filter Wheels, Turrets & Shutters
    • Controllers & Joysticks
    • Robotic Sample Loaders
    • Physiology Platforms
    • Motorized Vertical Stages
  • Microscope Automation
    • Evident Olympus Microscope Automation
    • Nikon Microscope Automation
    • Leica Microscope Automation
    • Zeiss Microscope Automation
    • Automated Custom Imaging Systems
    • Other Microscope Brands
  • Nanopositioning Devices
  • Vibration Control
  • Custom Solutions & Contract Manufacturing
Home » Blog » Adaptive Autofocus Empowers Microscopy: A Technical Overview

Adaptive Autofocus Empowers Microscopy: A Technical Overview

16.12.24

Microscopy continues to evolve with advancing technology, and automated focusing systems have become crucial for various applications. This article explores how hardware-based autofocus systems work and how Prior Scientific is advancing the technology to accommodate new sample types, including microfludics, in research and industry.  

It is based on a webinar presented at the 2024 Biophotonics Conference by Simon Bush, product manager at Prior Scientific. You can view the full webinar here.

Understanding Hardware Autofocus: Basic Principles 

Hardware autofocus systems differ fundamentally from traditional contrast-based autofocus methods. While contrast-based systems analyze the sample image itself, hardware autofocus uses direct light reflection for focus determination. The system collects reflections either from the sample's surface or from planes within the sample that have refractive index changes. A control loop then adjusts the microscope's focusing system to maintain or recapture focus automatically.  

This video shows a variety of different samples that have been arrayed together under a microscope objective. The samples were chosen to present a range of materials – metals and plastics – that reflect and interact with the light coming from the autofocus in different ways.  

We’ve used one of Prior’s motorized stages to scan around the combined samples to demonstrate that, regardless of the sample material, its structure and different levels of reflectivity, the PureFocus850 maintains focus on the sample.  

How Hardware Autofocus Works 

Hardware autofocus systems contain either an LED or laser diode that emits light onto the sample, reflected by a dichroic mirror (represented by the green line on the diagram below). The signal is collected and detected by a sensor (shown by the blue line on the diagram). When the sample moves out of focus, the system detects a defocus signal and adjusts accordingly. To determine focus direction, the system fills only half of the objective's back aperture, allowing for directional detection of focus changes. 

The imaging process is unaffected by hardware autofocus: Prior’s PureFocus850 can be positioned anywhere in the microscope’s infinity space and will allow transmission of all visible light wavelengths, enabling it to be used with fluorescence microscopy and ensuring that image color balance is unaffected. Color cameras typically do not detect the weak 850 nm wavelength light emitted by the PureFocus, and any stray light that may be detected by higher-end cameras can easily be blocked by installing a shortpass filter.  

Key Applications for Hardware Autofocus 

There are a wide range of applications and uses for hardware autofocus in both life science and industrial microscopy.  

1. Time lapse imaging 

  • Focus is maintained on cells over a 24-48 hour period to look for changes in morphology or changes in the expression of different proteins.  

  • Medical devices and microfluidics where samples are dynamic and temporal resolution is necessary. 

  • Microfluidics systems, organoids or other life science samples with depth, where contrast-based autofocus will not be able to locate the same image plane at each time point.  

2. Industrial Inspection 

  • In a laboratory setting or above an inline processing routine, where throughput is critical.  

  • Autofocus is ideal for semiconductor inspection because of the large sample sizes and complex surfaces.  

Major Advantages of Prior Scientific’s Hardware Autofocus 

Three key advantages of the PureFocus850 are: 

1. Speed and Efficiency 

  • Up to 95% reduction in scanning times compared to traditional methods 

  • Rapid focus capture without multiple image requirements: reduces volume of data for storage  

2. Sample Versatility 

  • Sample-agnostic operation 

  • Effective with low-contrast samples 

  • Works with sparse or diffuse fluorescence expressions 

3. Resistance to Environmental Factors 

  • Maintains focus despite thermal changes around the microscope: important for quality in time-lapse imaging 

  • Minimal impact on live cell environments as light sources used for imaging can be quite weak, which protects the cells 

The PureFocus850 also offers a number of specific benefits related to its features: 

Signal Processing Modes 

Prior’s PureFocus850 allows for processing samples with variations in height – such as semiconductor wafers. The system has two configurations which users can select to fit their requirements best:  

1. Slice Mode: Focuses on a specific point at the center of the field of view. 

  • Ideal for flat planes, tilted and undulating surfaces. 

  • Best-suited to glass slides, culture dishes and well plates. 

2. Line Mode: Takes weighted averages of signals detected from across the field of view. 

  • Better for samples with surface variations or weak reflectance. 

  • Provides more consistent focus across uneven surfaces. 

  • Best suited to industrial samples, semiconductor wafers or lab-on-a-chip devices. 

video here

Optical Path Integration 

The Prior PureFocus system mounts in the microscope's infinity space, offering flexible positioning options. This ensures that the PureFocus can be positioned behind the objective in fluorescence microscopes to avoid the autofocus laser signal being blocked, or in front of the tube lens in darkfield microscopes to ensure maximum suppression of stray light. It can even be positioned outside of the main optical axis for systems with space or path length constraints.  

Advanced Protection Features 

The Servo Limit Function represents a crucial safety advancement in autofocus technology. This system establishes fixed movement ranges relative to where the autofocus is first activated, effectively preventing objective crashes and protecting both samples and equipment. Particularly valuable when working with multiple samples, the function facilitates smooth movement between adjacent specimens while maintaining precise focus control. 

Dynamic Laser Power Adjustment 

The system's ability to automatically adjust laser power based on sample reflectivity represents a significant advancement in autofocus technology. This dynamic adjustment maintains optimal signal-to-noise ratios across varying sample types and conditions. The system continuously monitors and adapts to changes in material properties, ensuring consistent performance regardless of sample characteristics. 

Interface Correction  

Advanced interface correction methods form a crucial part of the system's capabilities. The technology effectively manages multiple reflections from sample layers, demonstrating sophisticated discrimination between different interfaces. This precise control allows the system to identify and focus on correct interfaces while avoiding false focus on unwanted surfaces, ensuring accurate and reliable imaging across complex sample structures. These features are essential for using the PureFocus850 with biological samples on slides or in well plates. 

System Performance and Safety Features 

Signal Quality Management 

The system employs comprehensive signal quality optimization techniques to ensure reliable performance. Through sophisticated signal-to-noise optimization and targeted filtering of interference sources, the autofocus maintains consistent accuracy. Mathematical correction algorithms further enhance signal clarity, providing robust focus maintenance across various imaging conditions. 

Sample Detection 

The integration of comprehensive safety features represents a key aspect of the system's design. Advanced crash prevention systems work in conjunction with continuous signal monitoring to protect both samples and equipment. If the signal intensity exceeds or drops below an allowed threshold, the autofocus will automatically deactivate.  

Conclusion 

Hardware-based autofocus systems represent a significant advancement in microscopy automation. Their ability to rapidly and accurately maintain focus across various sample types and conditions makes them invaluable tools in both research and industrial applications. With continued development of features like dynamic laser power adjustment and sophisticated signal processing, these systems are becoming increasingly adaptable and essential for modern microscopy applications. 

The PureFocus850 from Prior Scientific provides real-time focus control for most infinity-corrected optical systems and is suitable for both life science and industrial samples. Learn more about the PureFocus850 or request a demonstration.  

More Blogs

Close up of a motorized xy stage on an OpenStand-V inverted imaging platform. imaging platform 27.07.26

Microscopy and Precision Positioning Glossary: Terms, Definitions and Industry Guide

Learn More
H100A compact precision motorized XY stage for upright microscopes 15.06.26

H100A Compact Motorized XY Microscope Stage for Precision Microscopy: Product Manager Q&A

Learn More
Three quarters view of the Prior motorized filter cube turret for multi-colour fluorescence imaging. 13.05.26

How a motorized filter cube turret expands microscope performance across advanced imaging workflows

Learn More
HF108B Filter Wheel: High‑Speed Fluorescence Imaging for Automated Microscopy Systems 21.04.26

HF108B Filter Wheel: High‑Speed Fluorescence Imaging for Automated Microscopy Systems

Learn More

Footer

Products

  • Automated Imaging Systems
  • Imaging Components
  • Microscope Automation
  • Nanopositioning Devices

Company

  • Custom Solutions & Contract Manufacturing
  • Applications
  • Technical Support
  • Careers

Resources

  • About
  • Blog
  • News
  • Contact Us

    Sign up to stay in the know...

    ✉

    Connect with us

    Prior Scientific Instruments Ltd.
    Units 3-4 Fielding Industrial Estate
    Wilbraham Road, Fulbourn
    Cambridge, CB21 5ET, UK

    inquiries@prior.com
    +44 (0)1223 881711

    Prior Scientific Inc.
    80 Reservoir Park Drive
    Rockland, MA. 02370
    U.S.A.

    info@prior.com
    +1 781 878 8442

    Prior Scientific Instruments GmbH
    Maria-Pawlowna-Str. 4
    07743 Jena
    Germany

    jena@prior.com
    +49 (0)3641 242 010

    Prior Scientific KK
    Kayabacho 3rd Nagaoka Bldg 10F,
    2-7-10, Nihonbashi Kayabacho
    Chuo-Ku, Tokyo 103-0025, Japan

    info-japan@prior.com
    +81 (0)3 5652 8831

    Prior Scientific Instruments (Suzhou) Ltd.
    Room 118, Meilihua Hemu Park,
    No. 393 Suhong Middle Road,
    Suzhou Industrial Park,
    Suzhou, 215000, China

    info-china@prior.com
    +86 (0)512 6617 5866

    Copyright © 2026 · Prior Scientific. Terms & Conditions | Privacy Policy | Impressum

    Manage Consent
    To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
    Functional Always active
    The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
    Preferences
    The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
    Statistics
    The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
    Marketing
    The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
    • Manage options
    • Manage services
    • Manage {vendor_count} vendors
    • Read more about these purposes
    View preferences
    • {title}
    • {title}
    • {title}